Is curtain walling structural?

No. Curtain walling is non-structural: it does not support the building. It carries its own dead load plus wind and other imposed loads, then transfers those loads back to the primary structure, such as the floor slabs, through fixings and brackets. The building frame stays responsible for holding everything up.

What loads does curtain walling carry?

  • Its own weight (glass, frames and panels)
  • Wind pressure and suction
  • Movement from the building, such as deflection and thermal movement

How is it fixed to the building?

Brackets anchor the mullions to the edge of each floor slab or to structural steel. Designers must allow for slab deflection and tolerances so the facade does not take loads it was not designed for.

Is structural glazing different?

Yes. Structural glazing bonds glass directly to the framework with high-strength silicone, so the glass can share load. Curtain walling uses a separate supporting frame and does not bear building loads.

Does that mean it needs no engineering?

No. The system still needs a structural calculation for wind loads and fixings, and the supporting structure must be checked to accept those loads. That depends on building height and exposure. BBL Windows provides curtain walling for commercial projects in North London.

Thinking about shop fronts or curtain walling? We supply and fit across London, with a 10-year guarantee on our products. Call 020 8800 1838 or request a quote.

Back to commercial glazing | all commercial glazing FAQs