Does curtain walling need to be fire rated?
Not always. Curtain walling itself is usually non-fire-resisting, but it must not let fire spread between floors or compartments. That means fire stops at floor slabs and cavity barriers in the cavity, designed to Approved Document B. Fire-rated glazing is only needed where the building design requires it.
What fire protection is normally required?
- Fire stopping where compartment floors and walls meet the facade
- Cavity barriers to limit fire and smoke travel in built-up walls
- Non-combustible or limited-combustibility materials where the regulations require them
How should fire stops be proven?
CWCT guidance points to fire stops tested to BS EN 1364-4 and used within the tested scope. Where no suitable test exists, a fire engineering assessment is the alternative, which is common on complex facades.
Does Approved Document B settle it?
Not on its own. It is based on traditional construction, so curtain walling often needs a fire engineer’s input. Height, use of the building and sprinklers all affect the answer. Since the June 2022 amendments, relevant metal composite material is banned on all buildings. BBL Windows works with design teams on curtain walling fire strategy requirements.
Thinking about shop fronts or curtain walling? We supply and fit across London, with a 10-year guarantee on our products. Call 020 8800 1838 or request a quote.